Recommended
Products
Preferred Cleaner:
Oasis 133 All Purpose Cleaner Preferred
Sanitizers:
Oasis 146
Mikroklene
Frequency:
Daily
Procedure:
- Clean
the cabinet and outside of the dispenser
with Oasis 133 All Purpose Cleaner. Dry with a
clean cloth. Do not use bleach, steel wool,
scouring pads or abrasives.
- To
clean the drip pan, pour warm water over
the cup rest and down the drip pan drain. Never
use hot water. Wipe down the inside walls of the
drip pan with solution of Oasis 133 All Purpose
Cleaner. Rinse with warm water and sanitize with 150-400
ppm Oasis 146
OR 25 ppm Mikroklene.
(Note: If ice bin is directly under dispenser
drip pan, make sure ice bin is empty or ice is completely
covered. Do not use drain cleaner, ammonia or bleach).
- To
clean the dispensing valves, remove the
nozzles and diffusers. Place them in sanitizing
solution (150-400 ppm Oasis 146 OR
25 ppm Mikroklene). Scrub each piece individually
with a brush. Allow them to soak for 15 minutes. Do
not use ammonia or bleach. Do not
wash them in an automatic dishwasher.
- Remove
the clean nozzles and diffusers from the solution. Thoroughly
rinse with warm water and allow to air dry.
- Use
a clean cloth and sanitizing solution to wipe clean all
exterior surfaces of dispenser, including dispenser valves
and underneath dispenser valves where nozzles and diffusers
connect to the valves.
- Reinstall
the nozzles and diffusers on the dispensing valves.
Frequency:
Weekly or when replacing a syrup container
Procedure:
- To
clean the syrup connectors, disconnect the syrup line from
the empty bag-in-box or figal tank. Soak the connectors
in warm water (100°F to 135°F / 38°C to 57°C)
for two to three minutes.
- Rinse
in warm water and reconnect them to a full syrup container.
- Rinse
the CO2 connector in warm water before reconnecting it to
a figal tank. This helps prevent leaks by making a good
seal.
Frequency:
Monthly
Procedure
- Ice Cooled Unit:
- Clean
the ice bins. Wash down the inside walls and the aluminum
surface of the cold plate with solution of Oasis 133
All Purpose Cleaner and a soft, clean cloth. Rinse
completely with clean, warm water.
Note: For operations with automatic ice
turners -- Unplug the unit before cleaning near the cold
plate.
- Sanitize
the interior surfaces with 150-400 ppm Oasis
146 OR 25 ppm Mikroklene using a spray bottle.
- Allow
to air dry.
Procedure
- Mechanical Refrigeration Unit:
- Check
the condenser. Unplug the dispenser and remove the grill
cover in front of the
condenser. Use a vacuum hose with a soft brush attachment
to gently clean the exposed surface of the condenser. Brush
in the same direction as the aluminum fins. To avoid bending
the fins and blocking air flow, do not push hard.
- If
your condenser is equipped with a foam filter,
the above steps are not necessary.
Instead, remove the foam filter and wash in Oasis 133
All Purpose Cleaner solution.
- Rinse
completely and allow to dry on flat surface.
- Reinstall
the foam filter when totally dry.
|